Search results for "electric [mass]"

showing 10 items of 1101 documents

Use of the residual capacities of existing reservoirs as storage of the electricity produced by grid-connected intermittent RES plants, by means of p…

2013

Energy StorageRenewable Energy Sources (RES)Pumped Hydroelectric storage (PHS)
researchProduct

Design, assembly and characterization of silicide-based thermoelectric modules

2016

ID: 1143 In: Energy conversion and management, 13-21. Summary: Highlights•Novel silicide-based thermoelectric modules were experimentally investigated.•The modules produced high power of 1.04 W at 405 °C and 3.24 W at 735 °C.•An estimated module efficiency of 5.3% represent the highest reported for silicide systems.AbstractSilicides have attracted considerable attention for use in thermoelectric generators due mainly to low cost, low toxicity and light weight, in contrast to conventional materials such as bismuth and lead telluride. Most reported work has focused on optimizing the materials properties while little has been done on module testing. In this work we have designed and tested mod…

Energy storageThermoelectric equipment02 engineering and technology7. Clean energyThermal expansionBismuthchemistry.chemical_compoundDegradationMagnesium silicideHigher manganese silicideSilicide0202 electrical engineering electronic engineering information engineeringHigher manganese silicidesMagnesiumThermo-Electric materialsThermal expansion mismatchDirect energy conversion[CHIM.MATE]Chemical Sciences/Material chemistryThermoelectric materialsMagnesium silicides[CHIM.THEO]Chemical Sciences/Theoretical and/or physical chemistryConversion directeFuel TechnologyThermal expansionSilicidesMaterials scienceMaximum power principleCharacterization020209 energyEnergy Engineering and Power Technologychemistry.chemical_elementMagnesium silicideThermoelectric moduleThermo-electric modulesElectronic engineering[CHIM.CRIS]Chemical Sciences/Cristallography[CHIM]Chemical SciencesManganeseRenewable Energy Sustainability and the EnvironmentEquivalent circuitsThermoelectricityEngineering physicsLead tellurideThermoelectric generatorCross-section areaNuclear Energy and EngineeringchemistryEnergy transferConventional materialsÉnergieMaterials propertiesThermoelectric generatorsMaterials testing
researchProduct

A set of indicators for arc faults detection based on low frequency harmonic analysis

2016

In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.

Engineering020209 energyArc-fault circuit interrupter02 engineering and technologyUL 1699Low frequencylaw.inventionArc (geometry)Harmonic analysisElectric arcarc fault circuit interrupter (AFCI)power system measurements power system harmonics fault diagnosis arc discharges interrupters arc faults detection home protection electrical safety series arcs arc fault circuit interrupter (AFCI) UL 1699lawhome protection0202 electrical engineering electronic engineering information engineeringElectronic engineeringSpectral resolutionpower system harmonicsinterruptersbusiness.industry020208 electrical & electronic engineeringarc faults detectionfault diagnosispower system measurementsFault indicatorElectrical networkarc dischargeselectrical safetybusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings
researchProduct

A mixed FES/EMG system for real time analysis of muscular fatigue

2010

International audience; In this article, we present a functional electrical stimulator allowing the extraction in real time of M-wave characteristics from resulting EMG recodings in order to quantify muscle fatigue. This system is composed of three parts. A Labview software managing the stimulation output and electromyogram (EMG) input signal, a hardware part amplifying the output and input signal and a link between the two previous parts which is made up from input/output module (NIdaq USB 6251). In order to characterize the fatigue level, the Continuous Wavelet Transform is applied yielding a local maxima detection. The fatigue is represented on a scale from 0 for a fine shaped muscle to …

Engineering0206 medical engineering02 engineering and technologyElectromyographyUSBSensitivity and SpecificitySignallaw.invention03 medical and health sciences0302 clinical medicinelawElectronic engineeringmedicineHumansMuscle SkeletalSimulationContinuous wavelet transformMuscle fatiguemedicine.diagnostic_testElectromyographybusiness.industryReproducibility of ResultsWavelet transformEquipment Design020601 biomedical engineeringElectric Stimulation[SPI.TRON] Engineering Sciences [physics]/Electronics[ SPI.TRON ] Engineering Sciences [physics]/Electronics[SPI.TRON]Engineering Sciences [physics]/ElectronicsEquipment Failure AnalysisMaxima and minimaMuscle Fatiguemedicine.symptombusinessAlgorithmsSoftware030217 neurology & neurosurgeryMuscle ContractionMuscle contraction2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
researchProduct

Structural Health Monitoring Procedure for Composite Structures through the use of Artificial Neural Networks

2015

In this paper different architectures of Artificial Neural Networks (ANNs) for structural damage detection are studied. The main objective is to investigate an ANN able to detect and localize damage without any prior knowledge on its characteristics so as to serve as a real-time data processor for Structural Health Monitoring (SHM) systems. Two different architectures are studied: the standard feed-forward Multi Layer Perceptron (MLP) and the Radial Basis Function (RBF) ANNs. The training data are given, in terms of a Damage Index ℑD, properly defined using a piezoelectric sensor signal output to obtain suitable information on the damage position and dimensions. The electromechanical respon…

EngineeringArtificial neural networkBasis (linear algebra)Piezoelectric sensorbusiness.industryComputer Science::Neural and Evolutionary ComputationPattern recognitionStructural engineeringData processing systemMultilayer perceptronPharmacology (medical)Radial basis functionArtificial intelligenceStructural health monitoringbusinessBoundary element methodAerotecnica Missili & Spazio
researchProduct

Numerical Analysis of Piezoelectric Active Repair in the Presence of Frictional Contact Conditions

2013

The increasing development of smart materials, such as piezoelectric and shape memory alloys, has opened new opportunities for improving repair techniques. Particularly, active repairs, based on the converse piezoelectric effect, can increase the life of a structure by reducing the crack opening. A deep characterization of the electromechanical behavior of delaminated composite structures, actively repaired by piezoelectric patches, can be achieved by considering the adhesive layer between the host structure and the repair and by taking into account the frictional contact between the crack surfaces. In this paper, Boundary Element (BE) analyses performed on delaminated composite structures …

EngineeringComposite numberlcsh:Chemical technologySmart materialBiochemistryArticleAnalytical Chemistryboundary element methodmedicinelcsh:TP1-1185Electrical and Electronic EngineeringSettore ING-IND/04 - Costruzioni E Strutture AerospazialiInstrumentationBoundary element methodbusiness.industryDelaminationStiffnessFracture mechanicspiezoelectric actuatorStructural engineeringShape-memory alloyfrictional contactPiezoelectricityAtomic and Molecular Physics and Opticsactive repairspring modelmedicine.symptombusinessSensors
researchProduct

Transient stability analysis for symmetrical and unsymmetrical faults in mixed three-phase and six-phase power systems

1989

Abstract The aim of this paper is to analyse the transient stability of a three-phase power system with six-phase lines interconnected by three-phase to six-phase transformers. For these mixed power systems a transient stability analysis is performed under all main types of disturbances (short-circuits, generator and load rejection, line outages), particularly in the case of faults at six-phase buses. A generalized procedure to evaluate transient stability is explained in detail. It is based on the symmetrical components method, which allows one to consider also unsymmetrical faults both at three-phase and six-phase buses. For every possible unsymmetrical short-circuit an equivalent fault a…

EngineeringComputer programbusiness.industryEnergy Engineering and Power TechnologySymmetrical componentslaw.inventionElectric admittanceElectric power systemThree-phaseControl theorylawElectronic engineeringmedicineTransient stability analysisElectrical and Electronic Engineeringmedicine.symptomLoad rejectionbusinessTransformerInternational Journal of Electrical Power & Energy Systems
researchProduct

Currents Distribution During a Fault in an MV Network: Methods and Measurements

2016

When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…

EngineeringDistribution (number theory)020209 energyGlobal earthing system02 engineering and technologyglobal earthing systemsFault (power engineering)Industrial and Manufacturing EngineeringFault current limiter0202 electrical engineering electronic engineering information engineeringmedicineCurrent distributionElectrical and Electronic EngineeringElectrical conductorsingle line to ground faultglobal earthing systems (GESs)Current distribution electrical safety global earthing systems (GESs) grounding power distribution faults power system faults single line to ground fault (SLGF)business.industryGroundElectric shockElectrical engineeringpower system faultsgroundingmedicine.diseaseGridSingle linecurrent distribution; electrical safety; global earthing systems; grounding; power distribution faults; power system faults; single line to ground fault; control and systems engineering; industrial and manufacturing engineering; electrical and electronic engineeringSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaSettore ING-IND/31 - ElettrotecnicaPower system faultControl and Systems Engineeringsingle line to ground fault (SLGF)power distribution faultselectrical safetybusinessCurrent distribution; electrical safety; global earthing systems (GESs); grounding; power distribution faults; power system faults; single line to ground fault (SLGF); Control and Systems Engineering; Industrial and Manufacturing Engineering; Electrical and Electronic EngineeringPower distribution fault
researchProduct

A Simple Method for Evaluating Ground-Fault Current Transfer at the Transition Station of a Combined Overhead-Cable Line

2008

When a substation is fed by a combined overhead-cable transmission line, a significant part of the ground fault current flows through cable sheaths and is discharged into the soil at the transition station where cables are connected to the overhead line. Such a phenomenon, known as ldquofault application transfer,rdquo may result in high ground potentials at the transition station which may cause shocks and equipment damage. The scope of this paper is to present new analytic formulas which can be used for the direct calculation of the fault current transferred at the transition station and its ground potential rise as well as the substation earth current. The proposed formulas allow evaluat…

EngineeringGroundbusiness.industryElectric shockAerial cableElectrical engineeringEnergy Engineering and Power TechnologyFault application transfer ground fault current distribution grounding safety conditions.medicine.diseaseFault (power engineering)Line (electrical engineering)law.inventionlawTransmission lineOverhead cablemedicineElectrical and Electronic EngineeringbusinessOverhead line
researchProduct

Performance of two innovative stress sensors imbedded in mortar joints of new masonry elements

2021

Abstract Many historical cities enjoy the presence of masonry buildings with inestimable historical, artistic and cultural value. Old masonry buildings often suffer structural deficiencies, design faults and materials aging process. In recent years, many researchers focused their attention on the opportunities that structural health monitoring (SHM) can ensure for the health state of existing masonry structures, where damage can be difficult to be promptly predicted, pontentially causing abrupt collapses, with high risks for the community. This paper presents an experimental study on the effectiveness of two types of stress sensor for SHM of new masonry elements. Ceramic piezoelectric senso…

EngineeringPiezoelectric sensorCapacitive stress sensorCapacitive sensing0211 other engineering and technologiesUniaxial compressionExperimental testing020101 civil engineering02 engineering and technology0201 civil engineering021105 building & constructionGeneral Materials ScienceCapacitive stress sensorsCivil and Structural EngineeringMasonry wallStructural health monitoringStress sensorbusiness.industryStress sensorsMasonry wallsBuilding and ConstructionStructural engineeringCapacitive stress sensors Experimental testing Masonry walls Piezoelectric stress sensors Structural health monitoringMasonryCapacitive stress sensors; Experimental testing; Masonry walls; Piezoelectric stress sensors; Structural health monitoringSettore ICAR/09 - Tecnica Delle CostruzioniPiezoelectric stress sensorsPiezoelectric stress sensorStructural health monitoringMortarbusiness
researchProduct